CLOSED  Bug report #766  -  Subparameters of Switch convert points to the same value
Posted Jan 23, 2015 - updated Jan 05, 2019
action_vote_minus_faded.png
0
Votes
action_vote_plus_faded.png
icon_info.png This issue has been closed with status "Fixed" and resolution "RESOLVED".
Issue details
  • Type of issue
    Bug report
  • Status
     
    Fixed
  • Assigned to
    Not assigned to anyone
  • Progress
       
  • Type of bug
    Not triaged
  • Likelihood
    Not triaged
  • Effect
    Not triaged
  • Posted by
     Carlos López
  • Owned by
    Not owned by anyone
  • Category
    Not determined
  • Resolution
    RESOLVED
  • Priority
    Not determined
  • Targetted for
    icon_milestones.png 1.0.2
  • Tags
    icon_customdatatype.png switch
  • Difficulty
    icon_customdatatype.png Not determined
Issue description
Windows 32 bits development release ID: f7d3b1

Convert any parameter to Switch convert type. The two subparameters (Link On and Link Off) have always the same value regardless what you enter on the value entry.
Steps to reproduce this issue
Nothing entered.

#4
Comment posted by
 Permutator
Jul 20, 23:53
I submitted a pull request to fix this.